Skip to content

BIMCO welcomes new requirement for water level detectors in holds of non-bulk ships

Shipping organisation BIMCO has welcomed the new requirement for dry cargo vessels other than bulkers to install water levels adopted at MSC 103 last week.

SOLAS currently requires only single hold cargo ships of less than 80 meters (100 meters if constructed before 1 July 1998) to have a water level detection alarm. At MSC 100 it was agreed to include requirements for water level detectors on non-bulk carrier cargo ships with multiple cargo holds.

The sinking of El Faro on 1 October 2015 provides an example of why this is necessary, as the ship sank following flooding, with loss of all hands onboard. Recommendations from the accident report proposed that “new cargo vessels be equipped with bilge high-level alarms in all cargo holds that send audible and visible indication to a manned location.”

Hence, the MSC adopted new regulation, entering into force on 1 January 2024. The new provision is put forward in a new SOLAS regulation (II-1/25-1) which requires new multiple-hold cargo ships to be fitted with water level detectors in each cargo hold intended for cargo.

The water level detectors will give an audible and visual alarm at the navigation bridge when the water level reaches a hight of 0.3m above the bottom of the cargo hold, and again when the water level reaches a hight of 15% of the depth of the cargo hold. If the ship is having bilge pumping arrangements (according to SOLAS II-1/35-1) this may be used as equivalent too, if positioned correctly in the cargo holds.

The new regulation harmonizes the requirements for bulk carriers and non-bulk carriers, and will not apply to tankers, liquid holds, and tanks entirely above the freeboard deck. MSC 103 also agreed to consequential amendments to the “Performance standards for water level detectors on bulk carriers and single hold cargo ships other than bulk carriers” (MSC.188(79)) to align with the new SOLAS requirements.